Load catalogues and set default data for the project
Общи данни window
Tab - Изчислителни раздели (модули) - specify scope of project: Отоплителни системи / Охладителни системи.
Tab - Управление на етажи – verify and specify basic parameters:
Етажна височина
Default distance between ceiling and distribution pipe-runs to radiant panel system (ΔHуч.пан.)
Default distance between ceiling and radiant panels by entering the value in field (Дебелина на окачен таван)
Tab - Каталози – load product catalogues required for the project.
Tab - Термални системи / Източници – verify parameters: Използване на източник подразбиране and supply temperature (θs,О).
Tab - Термални системи / Разпределителна система / Виртуални връзки на лъчисти системи - select option Позволи системи без колектори.
Tab - Термални системи / Разпределителна система / Pipes and insulation - types and default data – specify default pipe and insulation types, verify temperatures in fields Околна температура по подразбиране на участък.
Tab - Лъчисти системи / Панели – specify default types and sizes of radiant panels and correct the minimum (Δθ мин.) and maximum (Δθ макс.) values of permissible temperature drop of the medium. Optimum value will be determined within the interval for every radiant panel in order to attain the required output.
Insert the radiant panel using the icon Тавенен панел in group Лъчисто
Adjust the length of the radiant panel to the dimensions of the room by dragging terminal points of the panel and expanding it. The length of the panel in the drawing does not have to correspond to the real length of a single panel. Based on the required length, the program will assemble a set of base panels and connection headers connected in series with its total length coresponding to the required length.
Insert subsequent radiant panels by clicking again the Тавенен панел icon or by copying panels already inserted. When necessary modify the settings of the АВТО mode.
Initial calculations - diagnostics of the heat demand coverage in room
Run radiant heating calculations by clicking the Файл:Suz-rh-cal-op.png icon in the Изчисления group.
required drop of temperature of the medium in the radiant panel (Δθнеоб.,О). Файл:Radiant-ceiling-steel-panel-wychlodzenie.PNG4. Adjustment of temperature drop of medium in radiant panel (Δθwym,H)
number/size of radiant panels
Recalculate the project – verify the effect of the changes made on the attained heating output.
Edit installation - append drawings with the medium distribution system
Upon attaining satisfactory results for the coverage of heat demand in rooms, insert the other components of the system (source, pipe-runs, fittings) and connect them to the radiant panels.
Make complete calculations including system balancing and bill of materials
Make calculations for radiant heating by clicking the Файл:Suz-rh-cal-op.png icon in the Изчисления group.
Verify the diagnostics and calculation results, in particular:
Required source parameters - Резултати window – Резултати от отопление/Общи резултати от отопление tab
Flow balance – Резултати window – Кръгове tab
Bill of materials - Резултати window – Количествена сметка на материали - отопление / охлаждане tab За повече информация, моля вижте:Calculations and diagnostics
Verify visually arrangement of the system in 3D view
Verify the drawing style of the panel in 2D and 3D views and the level of detail of information provided in the label. Configuration is given in the Общи данни window.